BUILDING CODES

BUILDING CODES

BUILDING CODES

All CornerStone Designs house plans are designed to comply with the International Residential Code (IRC). Some states, counties and local jurisdictions have additional building codes, zoning requirements, and other regulations that may apply to your project. Modifications may be necessary to meet these local codes, most notably regarding site-specific earthquake loads, special wind loads, increased snow loads, soils conditions, flood plain and critical areas issues. CornerStone Designs plans are not designed to comply with IRC prescriptive wall bracing requirements and may require site-specific lateral (wind & earthquake) engineering calculations stamped by a Professional Engineer (PE) licensed in your state. Please check with your local building department to determine the specific requirements that will apply to your site.

Architects Northwest Standard Design Loads

Roof
Roof

15 PSF Dead Load + 25 PSF Live Load= 40 PSF

Floor
Floor

10 PSF Dead Load + 40 PSF Live Load= 50 PSF

Ceiling
Ceiling

05 PSF Dead Load + 10 PSF Live Load= 15 PSF

Deck
Deck

05 PSF Dead Load + 40 PSF Live Load= 45 PSF

Interior Wall
Interior Wall

07 PSF

Exterior Wall
Exterior Wall

10 PSF

Snow Load
Snow Load

25 PSF

Wind Load
Wind Load

85 PSF

Wind Exposure
Wind Exposure

B

Seismic Category
Seismic Category

D

Architects Northwest Standard Beam Design Deflection Criteria

Roof
Roof

15 PSF Dead Load + 25 PSF Live Load= 40 PSF

Floor
Floor

10 PSF Dead Load + 40 PSF Live Load= 50 PSF